3. Commands
3-128 July 2004 4821-A2-GB21-00
Show System Options
show system options
Minimum Access Level: User
The show system options command shows the system configuration.
Example:
PDYN> show system options
test-time-out 5 minutes
date-display-format dd/mm/yy
inactivity-time-out 5 minutes
spectrum management enabled
PDYN>
Display results:
test-time-out – The amount of time a disruptive test is allowed to run.
date-display-format The format of dates displayed and accepted by the system:
– dd/mm/yy – Day, month, year.
– mm/dd/yy – Month, day, year.
inactivity-time-out – The amount of time before an inactive CLI session is terminated.
spectrum management – Tells if the DSL line is using spectrum management.
alarm threshold temperature high - High alarm threshold for temperature sensor
alarm threshold temperature low – Low alarm threshold for temperature sensor