4 June 2005 MIM4-A2-GZ41-00
Connecting the T1 Line
A primary feature of the MIM-4T1 is loop bonding capability, though the module
can function with a single T1 connection as well.
NOTE: A MIM-4T1 must be connected with T1 provider equipment; a connection
between the MIM-4T1 and T1 subscriber equipment will not function.
Loop Bonded Connection
Using multiple T1 lines for one network connection (loop bonding ) multiplies the
speed and data passing capability of the connection. Multiple T1 lines also provide
backup should any of the lines become disabled. A MIM-4T1 can only establish
loop bonded connections with other loop bonding capable T1 provider equipment;
refer to the T1 Loop Bonding Product to Product Feature Compatibility list
(Document Number COMP-A2-GK43 ).
Procedure
1. If ferrite chokes are supplied with your MIM:
Open a ferrite choke.
One or two cables will fit in the ferrite choke. Make a loop at the end of
your cables and close them in the ferrite choke. Position the choke as
close as possible to the RJ48C connectors.
Snap shut the ferrite choke.
2. Plug your T1 cables into the T1 RJ48C ports on the MIM-4T1 faceplate; the
order of connection is not important.
3. Verify all connections: the Port Lnk LEDs on the MIM-4T1 faceplate will flash
green to indicate the connections are established and operational.
04-17593